- Index
- December 2023
STR — Store Task Register
Opcode | Instruction | Op/En | 64-Bit Mode | Compat/Leg Mode | Description |
---|---|---|---|---|---|
0F 00 /1 | STR r/m16 | M | Valid | Valid | Stores segment selector from TR in r/m16. |
Instruction Operand Encoding ¶
Op/En | Operand 1 | Operand 2 | Operand 3 | Operand 4 |
---|---|---|---|---|
M | ModRM:r/m (w) | N/A | N/A | N/A |
Description ¶
Stores the segment selector from the task register (TR) in the destination operand. The destination operand can be a general-purpose register or a memory location. The segment selector stored with this instruction points to the task state segment (TSS) for the currently running task.
When the destination operand is a 32-bit register, the 16-bit segment selector is copied into the lower 16 bits of the register and the upper 16 bits of the register are cleared. When the destination operand is a memory location, the segment selector is written to memory as a 16-bit quantity, regardless of operand size.
In 64-bit mode, operation is the same. The size of the memory operand is fixed at 16 bits. In register stores, the 2-byte TR is zero extended if stored to a 64-bit register.
The STR instruction is useful only in operating-system software. It can only be executed in protected mode.
Operation ¶
DEST := TR(SegmentSelector);
Flags Affected ¶
None.
Protected Mode Exceptions ¶
#GP(0) | If the destination is a memory operand that is located in a non-writable segment or if the effective address is outside the CS, DS, ES, FS, or GS segment limit. |
If the DS, ES, FS, or GS register is used to access memory and it contains a NULL segment selector. | |
If CR4.UMIP = 1 and CPL > 0. | |
#SS(0) | If a memory operand effective address is outside the SS segment limit. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3. |
#UD | If the LOCK prefix is used. |
Real-Address Mode Exceptions ¶
#UD | The STR instruction is not recognized in real-address mode. |
Virtual-8086 Mode Exceptions ¶
#UD | The STR instruction is not recognized in virtual-8086 mode. |
Compatibility Mode Exceptions ¶
Same exceptions as in protected mode.
64-Bit Mode Exceptions ¶
#GP(0) | If the memory address is in a non-canonical form. |
If CR4.UMIP = 1 and CPL > 0. | |
#SS(0) | If the stack address is in a non-canonical form. |
#PF(fault-code) | If a page fault occurs. |
#AC(0) | If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3. |
#UD | If the LOCK prefix is used. |